{"id":335,"date":"2026-04-03T09:14:53","date_gmt":"2026-04-03T01:14:53","guid":{"rendered":"https:\/\/gd-penglong.com\/?post_type=product&#038;p=335"},"modified":"2026-04-03T09:24:05","modified_gmt":"2026-04-03T01:24:05","slug":"mineral-insulated-fire-rated-cable","status":"publish","type":"product","link":"https:\/\/gd-penglong.com\/index.php\/product\/mineral-insulated-fire-rated-cable\/","title":{"rendered":"Mineral Insulated Fire-Rated Cable"},"content":{"rendered":"<h2>Product Advantage<\/h2>\n<p>Improved Durability with top quality manufactured insulation ensuring full compliance with industry standards, designed to withstand extreme temperatures, moisture and physical harms<\/p>\n<p>RRH Cable we have the capability to manufacture grade A 99.9% pure copper precisely stranded in the insulators for the best conductivity and efficiency<\/p>\n<p>Thanks to our expert craftsmanship, we provide high-quality cables that minimize the need for frequent maintenance or replacements, significantly reducing long-term operational costs.<\/p>\n<h2>Technical Parameters<\/h2>\n<h6>Size(mm\u00b2)\u00a0 \u00a0AWG\u00a0 \u00a0Voltage Rating\u00a0 Ampacity (A) Insulation\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Armor\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Shielding\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Conductor Material\u00a0 \u00a0 \u00a0 Core Type\u00a0 \u00a0# Conductors Temp Rating (\u00b0C)\u00a0 \u00a0 # Strands<br \/>\n1.0 mm\u00b2\u00a0 \u00a0 \u00a017 AWG\u00a0 300\/500V\u00a0 \u00a0 \u00a016\u201320 A\u00a0 \u00a0 \u00a0 \u00a0Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper\u00a0 Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a01\u20134\u00a0 \u00a0 \u00a0 \u00a0250\u00b0C normal \/ up to 950\u00b0C fire Solid (no strands)<br \/>\n1.5 mm\u00b2\u00a0 \u00a0 \u00a015 AWG\u00a0 300\/500V\u00a0 \u00a0 \u00a020\u201325 A\u00a0 \u00a0 \u00a0 \u00a0Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper\u00a0 \u00a0Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 1\u20134\u00a0 \u00a0 \u00a0 \u00a0250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n2.5 mm\u00b2\u00a0 \u00a0 13 AWG\u00a0 300\/500V\u00a0 \u00a0 \u00a0 25\u201332 A\u00a0 \u00a0 \u00a0 \u00a0Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper\u00a0 \u00a0Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 1\u20134\u00a0 \u00a0 \u00a0 \u00a0250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n4.0 mm\u00b2\u00a0 \u00a0 11 AWG\u00a0 600\/1000V\u00a0 \u00a032\u201341 A\u00a0 \u00a0 \u00a0 \u00a0 Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper\u00a0 Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a01\u20134\u00a0 \u00a0 \u00a0 \u00a0 250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n6.0 mm\u00b2\u00a0 \u00a0 9 AWG\u00a0 600\/1000V\u00a0 \u00a0 41\u201353 A\u00a0 \u00a0 \u00a0 \u00a0 Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a0 \u00a01\u20134\u00a0 \u00a0 \u00a0 \u00a0250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n10 mm\u00b2\u00a0 \u00a0 \u00a0 7 AWG\u00a0 600\/1000V\u00a0 \u00a0 \u00a057\u201370 A\u00a0 \u00a0 \u00a0 \u00a0Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a0 \u00a01\u20134\u00a0 \u00a0 \u00a0 \u00a0 250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n16 mm\u00b2\u00a0 \u00a0 \u00a0 5 AWG\u00a0 600\/1000V\u00a0 \u00a0 \u00a076\u201390 A\u00a0 \u00a0 \u00a0 \u00a0Magnesium Oxide Copper Sheath\u00a0 \u00a0Copper Sheath Copper Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a0 \u00a01\u20134\u00a0 \u00a0 \u00a0 \u00a0 250\u00b0C normal \/ up to 950\u00b0C fire Solid<br \/>\n25 mm\u00b2\u00a0 \u00a0 \u00a03 AWG\u00a0 600\/1000V\u00a0 \u00a0 \u00a0 99\u2013115 A\u00a0 \u00a0 \u00a0 Magnesium Oxide Copper Sheath\u00a0 Copper Sheath Copper Single Core \/ Multi-core\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 1\u20134\u00a0 \u00a0 \u00a0 \u00a0 \u00a0250\u00b0C normal \/ up to 950\u00b0C fire Solid<\/h6>\n<p><strong>Key Points<\/strong><\/p>\n<p>Fireproof at 950\u20131050\u00b0C for 3 hours.<\/p>\n<p>Zero smoke, zero toxic gases \u2014 important for human safety.<\/p>\n<p>High mechanical strength \u2014 resists crushing, cutting, and impact.<\/p>\n<p>Moisture resistant, chemical resistant, and corrosion resistant.<\/p>\n<p>Long service life \u2014 typically 30\u201350+ years even in tough environments.<\/p>\n<p>Armor \u2014 The copper sheath itself serves as mechanical protection (acts as armor).<\/p>\n<p>Shielding \u2014 The copper sheath naturally provides EMI shielding.<\/p>\n<p>Conductor Type \u2014 Always solid, not stranded, for best fire survival performance.<\/p>\n<p>Core Options \u2014 Available in single-core and multi-core (up to 4C usually).<\/p>\n<p>Fire Rating \u2014 Survives temperatures up to 950\u00b0C (BS 6387 CWZ fire test).<\/p>\n<p>Installation \u2014 Must be carefully bent; MI cables are rigid compared to regular cables.<\/p>\n<p><strong>Product Uses<\/strong><br \/>\nEmergency Power Circuits maintain power to critical systems like fire pumps, alarms, and emergency lighting during a fire.<\/p>\n<p>Fire Alarm and Detection Systems ensure alarms and detection systems continue to operate even under extreme heat.<\/p>\n<p>Smoke Extraction and Ventilation Fans keep ventilation systems running to remove smoke and protect escape routes.<\/p>\n<p>Hospital Life-Safety Systems power critical equipment (ICU systems, emergency lifts) in case of fire.<\/p>\n<p>Subway, Tunnel, and Airport Infrastructure maintain communication, lighting, and safety controls under fire.<\/p>\n<p>Oil &amp; Gas and Chemical Plants safeguard hazardous environments where fire or explosion resistance is critical.<\/p>\n<p>High-Rise Buildings and Commercial Complexes support evacuation systems, sprinklers, fire lifts, and PA (Public Address) systems.<\/p>\n<p><strong>Product Operate Guide<\/strong><br \/>\nApply cable base on its insulation property<\/p>\n<p>Always de-energize the system before working on cables<\/p>\n<p>Proper PPE duing operation<\/p>\n<h2><strong>Key Features<\/strong><\/h2>\n<p>Feature\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Why It Matters<br \/>\nFire Resistance up to 1050\u00b0C\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Ensures circuit integrity during fires for 3+ hours, crucial for evacuation and emergency systems.<br \/>\nInorganic Insulation (Magnesium Oxide)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Will not burn, melt, or produce toxic gases \u2014 enhances life safety and environmental safety.<br \/>\nCopper or Alloy Sheath\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Provides mechanical protection, corrosion resistance, and acts as an earth conductor.<br \/>\nZero Smoke and Zero Halogen\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Prevents vision loss and toxic exposure during a fire, critical for safe evacuation.<br \/>\nWaterproof and Chemical Resistant\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Allows use in wet, aggressive environments like tunnels, subways, and chemical plants.<br \/>\nHigh Mechanical Strength\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Resists impact, vibration, and crushing, maintaining function even in disaster conditions.<br \/>\nSmall Diameter and Flexible Design\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Easier to install through tight spaces, conduits, and difficult architectural areas.<br \/>\nLong Lifespan (30\u201350+ years)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Reduces long-term replacement and maintenance costs, maximizing reliability.<br \/>\nShielded Design\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Reduces electromagnetic interference (EMI), ideal for sensitive control and communication circuits.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mineral Insulated Fire-Rated Cables are specialized cables designed to maintain circuit integrity during extreme conditions like fire, heat, and mechanical impact.<br \/>\nThey are built with a copper sheath and magnesium oxide (MgO) insulation, making them naturally fireproof.<\/p>\n","protected":false},"featured_media":306,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":{"0":"post-335","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-products","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product\/335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/comments?post=335"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/media\/306"}],"wp:attachment":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/media?parent=335"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=335"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=335"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}