{"id":356,"date":"2026-04-07T15:49:59","date_gmt":"2026-04-07T07:49:59","guid":{"rendered":"https:\/\/gd-penglong.com\/?post_type=product&#038;p=356"},"modified":"2026-04-07T15:54:11","modified_gmt":"2026-04-07T07:54:11","slug":"flame-retardant-cable","status":"publish","type":"product","link":"https:\/\/gd-penglong.com\/index.php\/product\/flame-retardant-cable\/","title":{"rendered":"Flame Retardant Cable"},"content":{"rendered":"<p>Flame Retardant Cables by RRH are engineered to minimize fire risks, making them essential for public buildings, industrial facilities, and residential complexes. These cables are constructed with insulation and sheathing materials (like halogen-free compounds or flame-retardant PVC) that resist ignition and slow the spread of fire, buying valuable time for evacuation and fire suppression. Unlike standard cables, they emit minimal smoke and toxic fumes when exposed to high heat, reducing health hazards in enclosed spaces. RRH\u2019s flame retardant cables meet strict fire safety standards (such as IEC 60332 and UL 94), making them suitable for hospitals, schools, airports, and power plants where fire safety is paramount. Available in various types\u2014power, data, and control cables\u2014they ensure critical systems (like fire alarms, emergency lighting, and elevators) remain operational longer during a fire. Whether retrofitting an old building or constructing a new one, these cables add a vital layer of fire protection.Flame Retardant Cable<\/p>\n<h2><strong>Product Advantage<\/strong><\/h2>\n<p>Improved Durability with top quality manufactured insulation ensuring full compliance with industry standards, designed to withstand extreme temperatures, moisture and physical harms<\/p>\n<p>RRH Cable we have the capability to manufacture grade A 99.9% pure copper precisely stranded in the insulators for the best conductivity and efficiency<\/p>\n<p>Thanks to our expert craftsmanship, we provide high-quality cables that minimize the need for frequent maintenance or replacements, significantly reducing long-term operational costs.<\/p>\n<h2><strong>Technical Parameters<\/strong><\/h2>\n<h6>Cable Type\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0AWG Size\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0mm\u00b2\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Voltage Rating\u00a0 \u00a0 \u00a0Ampacity\u00a0 \u00a0 \u00a0 \u00a0Insulation Type\u00a0 \u00a0 \u00a0 \u00a0Conductor Material\u00a0 \u00a0 \u00a0 Core Type\u00a0 \u00a0 \u00a0 No. of Conductors\u00a0 \u00a0 Operating Temperature<br \/>\nFR PVC Power Cable\u00a0 \u00a010 \u2013 22 AWG\u00a0 0.34 \u2013 5.3\u00a0 300V \/ 600V\u00a0 \u00a0 \u00a03 \u2013 30 A\u00a0 \u00a0 \u00a0FR PVC\u00a0 \u00a0 \u00a0 Stranded Copper\u00a0 \u00a0 \u00a0 \u00a0 Single or Multicore\u00a0 \u00a0 \u00a0 \u00a0 \u00a01 \u2013 4C \/ 3C+E\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u201310\u00b0C to +70\u00b0C<br \/>\nFRLS Power Cable\u00a0 \u00a0 \u00a0 \u00a0 14 \u2013 4 AWG\u00a0 \u00a0 \u00a02.5 \u2013 25\u00a0 \u00a0 600V \u2013 1kV\u00a0 \u00a0 \u00a015 \u2013 60 A\u00a0 \u00a0FRLS (Low Smoke PVC)\u00a0 \u00a0Stranded Copper Multicore\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a02 \u2013 5\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u201315\u00b0C to +85\u00b0C<br \/>\nLSZH Instrumentation Cable\u00a0 16 \u2013 22 AWG\u00a0 0.5 \u2013 1.5\u00a0 \u00a0300V \u2013 600V\u00a0 \u00a02 \u2013 5 A\u00a0 \u00a0 XLPE \/ LSZH\u00a0 \u00a0 \u00a0 \u00a0 \u00a0Tinned Copper\u00a0 \u00a0 Pairs \/ Triads\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 1 \u2013 24 Pairs\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u201320\u00b0C to +90\u00b0C<br \/>\nControl Cable (FR)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 12 \u2013 22 AWG\u00a0 \u00a00.34 \u2013 4.0\u00a0 \u00a0 300V \u2013 1000V\u00a0 \u00a04 \u2013 30 A\u00a0 \u00a0XLPE \/ PVC \/ LSZH Bare\/Tinned Copper Multicore\u00a0 \u00a0 \u00a02 \u2013 61C\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u201325\u00b0C to +90\u00b0C<br \/>\nHalogen-Free Data Cable\u00a0 24 \u2013 20 AWG\u00a0 0.20 \u2013 0.52\u00a0 48V (PoE) \/ 300V ~0.5 \u2013 5 A\u00a0 LSZH Solid \/ Stranded Copper\u00a0 \u00a0 Twisted Pair\u00a0 \u00a0 \u00a0 \u00a04 pairs (Cat5e\/6)\u00a0 \u00a0 \u201320\u00b0C to +75\u00b0C<br \/>\nArmored FRLS Cable\u00a0 \u00a0 \u00a0 \u00a0 \u00a014 \u2013 4 AWG\u00a0 \u00a0 \u00a02.5 \u2013 25\u00a0 \u00a0 \u00a0 \u00a0 600V \u2013 1.1kV\u00a0 15 \u2013 60 A\u00a0 \u00a0 FRLS \/ XLPE Stranded Copper\u00a0 \u00a0 \u00a0 \u00a0 \u00a0Multicore\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a02 \u2013 4C or 3.5C\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u201325\u00b0C to +90\u00b0C<br \/>\nFire Alarm Cable\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a018 \u2013 16 AWG\u00a0 \u00a00.75 \u2013 1.5\u00a0 \u00a0300V \u2013 600V\u00a0 \u00a02 \u2013 5 A FR\u00a0 \u00a0PVC \/ LSZH Stranded Tinned Copper Twisted Pair \/ Shielded 1 \u2013 4 Pairs\u00a0 \u00a0\u201315\u00b0C to +70\u00b0C<br \/>\nElevator\/Building Cable\u00a0 \u00a016 \u2013 10 AWG\u00a0 \u00a01.0 \u2013 6.0\u00a0 \u00a0 300V \u2013 600V\u00a0 \u00a05 \u2013 35 A\u00a0 \u00a0 \u00a0 \u00a0 LSZH \/ FRLSH\u00a0 \u00a0 \u00a0 Stranded Copper\u00a0 \u00a0 \u00a0 Flat \/ Round\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 2 \u2013 24C\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u201320\u00b0C to +90\u00b0C<\/h6>\n<p><strong>Notes<\/strong><br \/>\nFR (Flame Retardant): Stops flame from propagating on the cable surface<\/p>\n<p>FRLS (Flame Retardant Low Smoke): Emits less smoke than standard FR<\/p>\n<p>LSZH (Low Smoke Zero Halogen): Minimal toxic and corrosive gas emissions<\/p>\n<p>XLPE (Cross-linked Polyethylene): High thermal resistance, used in FR applications<\/p>\n<p>Multicore: Multiple conductors under one outer sheath, common in control cables<\/p>\n<p>Triads\/Pairs: Used in instrumentation and signal cables for noise reduction<\/p>\n<p><strong>Product Uses<\/strong><br \/>\nCommercial Buildings Power and communication cabling in offices, malls, hospitals, etc.<\/p>\n<p>Industrial Facilities Motor, control, and signal cables in factories or process plants<\/p>\n<p>Mass Transit Systems Subways, trains, and buses require fire-safe wiring for public safety<\/p>\n<p>Oil &amp; Gas \/ Petrochemical Flame-resistant wiring in explosive or fire-risk zones<\/p>\n<p>Power Plants &amp; Utilities Cable trays, control rooms, and underground pathways<\/p>\n<p>Marine &amp; Offshore Shipboard cable systems where fire safety is critical<\/p>\n<p>Data Centers Safe data\/power cabling with low-smoke, halogen-free options<\/p>\n<p>Airports &amp; Stadiums Public venue installations with strict fire codes<\/p>\n<p>Tunnels &amp; Underground Systems Ventilation, lighting, and signaling cable networks with fire-retardant specifications<\/p>\n<p><strong>Product Operate Guide<\/strong><br \/>\nApply cable base on its insulation property<\/p>\n<p>Always de-energize the system before working on cables<\/p>\n<p>Proper PPE duing operation<\/p>\n<p><strong>Key Features<\/strong><\/p>\n<p>Feature\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Why It Matters<br \/>\nSelf-extinguishing\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Limits flame spread and potential damage<br \/>\nLow Smoke Emission\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Improves visibility and reduces inhalation risk during evacuation<br \/>\nLow\/Zero Halogen Emission\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Prevents release of corrosive gases that harm electronics and humans<br \/>\nCompliant with Fire Standards\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Required by international building and safety codes (IEC, UL, BS, EN standards)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Flame retardant cables are specially designed to resist the spread of fire along the cable's surface. They play a vital safety role in protecting life, equipment, and buildings by limiting flame propagation, smoke generation, and toxic gas emissions during fire events.<\/p>\n<p>Product Advantage<br \/>\nImproved Durability with top quality manufactured insulation ensuring full compliance with industry standards, designed to withstand extreme temperatures, moisture and physical harms<\/p>\n<p>RRH Cable we have the capability to manufacture grade A 99.9% pure copper precisely stranded in the insulators for the best conductivity and efficiency<\/p>\n<p>Thanks to our expert craftsmanship, we provide high-quality cables that minimize the need for frequent maintenance or replacements, significantly reducing long-term operational costs.<\/p>\n","protected":false},"featured_media":344,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":{"0":"post-356","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-products","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product\/356","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/comments?post=356"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/media\/344"}],"wp:attachment":[{"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/media?parent=356"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=356"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=356"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gd-penglong.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=356"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}